Subscribe to our Newsletter
Model No: MCV0214
Veterinary Doppler Blood Pressure Meter
MCS0001 Vet Vital Signs Patient Monitor is a reliable and efficient monitoring solution designed specifically for veterinary use. With its user-friendly interface and comprehensive monitoring capabilities, it ensures accurate vital signs measurement for animals of all sizes, from adult to pediatric and neonatal patients.
Quantity :
Veterinary Doppler Blood Pressure Meter
MCV0214
Veterinary Doppler Blood Pressure Meter:
Whether veterinary clinic or field setting, our meter ensures reliable monitoring of blood pressure in animals of all sizes.

Veterinary Doppler Blood Pressure Meter:

- the Doppler Blood Pressure Meter
- the valve on the blood pressure meter which is used to control inflating and deflating
- gasbag on the blood pressure meter which is used for inflating and deflating
- the high-sensitive probe
- 5 different sizes of cuffs
- charger of for the main machine
- earphone
- medical ultrasonic couplant
- the aluminum box which is used to contain all of the parts and for carrying
Veterinary Doppler Blood Pressure Meter Clinical application skills :
1.It is advised not to fasten the probe when in examination in the section of outpatient. Because the sound of artery will disappear when pet moves. It is better to press the probe with one’s finger. It is more time-saving and convenient to re-post the probe when the sound of artery disappears. When pets in operation is in anesthesia, it is better to fasten the probe with adhesive tape .
2.There is needing to apply a little more pressure to make the probe contact pets skin as much as possible .
3.It is advised to listen to the sound of pulse with earphone because the sound can be heard clearer and pets can be protected from being scared by the sound .
4.If using speaker, please appropriate volume. If too loud, it is not good to ear and some sound will be missed .
5.Keeping pet’s leg straight. If not, blood flow will be influenced and the examination result will not be so accurate .
6.It is better to do the measurement for 6 to 7 times so that pets become calm. And First few numerical values will be higher and following
2.There is needing to apply a little more pressure to make the probe contact pets skin as much as possible .
3.It is advised to listen to the sound of pulse with earphone because the sound can be heard clearer and pets can be protected from being scared by the sound .
4.If using speaker, please appropriate volume. If too loud, it is not good to ear and some sound will be missed .
5.Keeping pet’s leg straight. If not, blood flow will be influenced and the examination result will not be so accurate .
6.It is better to do the measurement for 6 to 7 times so that pets become calm. And First few numerical values will be higher and following